Jowuey Laser After-sales

Q1: What models of reflective mirrors and focus lenses are used for 150W, 180W, 300W? What focal length do they represent?

A1:
For 150W, the reflective mirror is 25 and the focusing lens is 20*63.5 with an 8mm focal length.
For 180W, the reflective mirror is 25 and the focusing lens is 20*63.5 with an 8mm focal length.
For 300W, the reflective mirror is 30 and the focusing lens is 25*127 with an 18mm focal length.

Q2: Selection of focus lens focal length: Which is suitable for engraving, and which for cutting?

A2:
1.50.8mm is used for engraving.
2.63.5mm is for cutting plates below 10mm or for engraving.
3.101.6mm is for cutting plates of 10-20mm.
4.127mm is for cutting plates of 10-30mm.

Q3: What is the problem if the material cannot be cut through?

A3:
1.Processing power level (whether the speed and power are matched).
2.Whether the optical path is straight and if there is light obstructions.
3.Whether all lenses are clean and free of coating defects.
4.Smoke obstructing light issue.
5. Laser tube lifespan (laser tubes are consumables, typically recommended for replacement after 1.5-2 years).

Q4: What causes non-circular cuts?

A4:
1. Draw lines using a low-power setting: (1390 model: 1100x800mm rectangle; 1325 model: 1100x2200mm rectangle) and measure     diagonals.
2. Check for mechanical looseness or gaps in the X and Y axes.
3. Check if the user parameters on the software are set too high.

Q5: Why does the material turn black during cutting?

A5:
1. Blackening when cutting wood materials is normal.
2. When cutting special materials, blow 0.2-0.4MPa air pressure to the laser head.
3. Caused by smoke; ensure timely exhaust.

Q6: What causes poor cutting quality?

A6:
1. Insufficient processing power setting.
2. Whether the focal length setting is accurate.
3. Whether the optical path is deviated.
4. Whether the laser head or focus lens is locked tightly.
5. Check for mechanical looseness and gaps in X and Y axes.
6. Check if the user parameters on the software are too high.

Q7: Why is there no laser output from the tube?

A7:
1. Check if the chiller is powered on.
2. Check if the water protection line is connected.
3. Check if the power is set on the software.
4. Test forced laser output from the power supply to determine if it’s the power supply or tube issue.

Q8: Why is the laser tube output weak?

A8:
1. Observe the color intensity of the laser tube during operation.
2. Low laser power supply current; adjust the ammeter.
3. Observe if the ammeter reading fluctuates during operation.
4. Measure if the laser power supply voltage is normal.

Q9: Why can’t the machine connect to the software?

A9:
1. Check if the PC cable or network cable is properly connected.
2. Check if the motherboard model on the software is automatically modified or matches.
3. Check if the correct connection method is selected on the software (USB auto or network connection).
4. For network settings, check if Local Connection Protocol 4 is manually set to (e.g., 192.168.1.99 or below).

Q10: When processing a full sheet, why do multiple cut pieces have inconsistent sizes?

A10:
1. Uneven material placement.
2. Excessive bed flatness error.
3. Inaccurate step distance.
4. Check for mechanical looseness and gaps in X and Y axes.
5. Motor step loss.
6. Driver issue; test by array-copying multiple rectangles and observe overlap accuracy.

Q11: How to troubleshoot laser interruption during operation?

A11:
1. During processing, use a multimeter to check if the laser output signal terminal on the motherboard has consistent voltage or any     changes.
2. Test the continuity of the chiller protection wine connector with a multimeter; and perform processing test with short circuit wire      to observe any changes.
3. During processing, use a multimeter to measure whether the signal terminal of the laser power supply has consistent voltage or        any changes.
4. If none of the above are issues, the problem is likely with the laser tube.

Q12: How to solve reversed CCD direction?

A12: Set the software origin position to be consistent with the reset point.

Q13: What to do if the edge following cannot find the mark point?

A13:
1. The Mark point diameter in the vector graph does not match the printed Mark diameter.
2. Adjust the ring light brightness.
3. Adjust contrast, exposure, similarity, and black/white template on the software.
4. Re-cut and match circles to test and calculate the scale.

Q14: How to solve distance and angle limitations during edge following?

A14: Adjust the distance deviation and angle deviation settings.

Q15: How to solve white edges when cutting materials?

A15: Adjust the air valve to reduce the blowing pressure at the laser head.

Q16: How to adjust the focal length?

A16: Move the focusing lens barrel up or down until the dot on the material is at its finest point, indicating the correct focal length.

Q17: How to solve chiller E3 low-temperature alarm?

A17:
1. Wait for the water temperature to rise after turning on the machine for a while.
2. If the low-temperature alarm persists, there may be a problem with the temperature control.

Q18: How to troubleshoot chiller E6 alarm?

A18:
1. E6 usually indicates the water pump or flow switch issue.
2. Test water flow by connecting the chiller’s inlet and outlet in series; if no flow, the pump may be faulty.
3. If the problem disappears after series connection, check for blockages or bends in the internal water pipes.
4. If the problem persists after series connection, replace the flow switch.

Q19: What causes chiller E2 high-temperature alarm?

A19:
1. The ambient temperature is too high during machine operation.
2. Excessive workload; allow the machine to rest periodically.
3. Dust accumulation in the chiller; clean it promptly.
4. Low or leaking refrigerant in the chiller.

Q19: What causes chiller E2 high-temperature alarm?

A19:
1. The ambient temperature is too high during machine operation.
2. Excessive workload; allow the machine to rest periodically.
3. Dust accumulation in the chiller; clean it promptly.
4. Low or leaking refrigerant in the chiller.

Q20: How to solve inaccurate cutting and white edges leakage during CCD edge following?

A20:
1. Ensure the vector graph for edge following and the printed pattern are of the same size (1:1).
2. Re-cut the cross calibration on the software.
3. Check if the material is placed flat.
4. Check for excessive bed flatness error.
5. Check for optical path misalignment or deviation.
6. Verify step distance accuracy.
7. Check for mechanical looseness or gaps in the X and Y axes.

Q21: Machine is protected(The control panel prompts “Machine is protected”).

A21: Check if the drive has any alarm.

Q22: Water protection failure.

A22:
1.Before the machine starts working, please make sure that the water tank is on.
2.Check whether the water protection signal cable is properly connected.

Q23: Underbuffering distance. The positioning point was too close to the boundary during engraving (the buffer distance exceeded the boundary).

A23: When positioning, we need to leave enough buffer distance on both sides of the picture, and the faster the speed, the more buffer distance is required. Press Exit first, and then move the laser head to the right to reserve enough buffer distance. Then click “Position” again to set a new starting point.

Q24: The X-axis/Y-axis border is out of bounds.

A24: The size of the graphics exceeds the working size of the machine.

Q25: Laser head can’t move left and right, click the control panel does not respond.

A25:
1.The X-axis limit switch is faulty. Find the limit switch on the left side of the X axis and check whether the wiring and contact rod of     the limit switch are in good condition.
2.X-axis motor interface contact is poor. If the X-axis limit switch works properly, open the upper right door panel of the machine        and check whether the interface of the X-axis motor is connected correctly.X-axis motor or drive is damaged. Open the lower           right door panel of the machine and check whether the red LED light on the X-axis driver flashes.

Q26: The laser head can’t move back and forth. Nothing happens when you click on the control panel.

A26:
1.The rotary shaft switch is turned on.
2.The Y-axis limit switch is faulty. Open the upper left door panel of the machine and check whether the wiring and contact rod of       the limit switch are intact.
3.Y-axis motor interface contact is poor. Open the rear door cover of the machine and check whether the Y-axis motor interface is       in poor contact.

Q27: The machine does not blow during the cutting process.

A27:
1.Air pump operation is controlled by software. Check the layer parameter “Blowing” option is turned on.
2.Check whether the regulating valve is open.
3.Check whether the air pump is faulty.

Q28: The exhaust fan cannot exhaust smoke.

A28:
1.Install the air inlet and outlet in the opposite direction.
2.Check whether the exhaust fan is faulty is to directly connect the power supply, use the power cable of the water tank to connect     the exhaust fan power cable connector, and then connect the power supply to check whether the exhaust fan can work normally.